| MODEL SELECTION GUIDE FOR ADV |
| MODEL |
ORIFICE
IN MM |
MWP
KG /CM 2 |
END
CONNECTION |
CFM/HP (APPROX.) |
HAVING
SLUDGE
AND OIL |
RE MARKS /
CONCLUSION |
| EDV-161 |
2.5 |
16 |
1/2" |
< 30 / 9 |
NO |
SUITABLE FOR LOW CAPACITY
COMPRESSOR UP TO 30 CFM |
| MOIST DRAIN |
2.5 |
15 |
1/2" |
< 30 / 9 |
NO |
SUITABLE FOR LOW CAPACITY
COMPRESSOR UP TO 30 CFM |
| MOIST DRAIN |
5 |
12 |
1/2" |
< 80 / 23 |
YES
WITH
STRAINER |
SUITABLE FOR LOW CAPACITY
COMPRESSOR UP TO 30 CFM AND BELOW 80 CFM. |
EDV.
401/
251/
351 |
0.8 |
40/
25/
35 |
1/2" |
< 30 / 9 |
NO |
COMPRESSOR BELOW 30 CFM BUT
HIGH PRESSURE |
| HDV-151 |
12.5 |
15 |
1/2" |
< 80 / 23 |
YES |
SUITABLE ABOVE 80 CFM AND
CONDENSATE HAVING SLUDGE /OIL |
| HDV-152 |
25 |
15 |
1" |
<500 / 142 |
YES |
FOR 1" LINE SIZE FULL ORIFICE
SUITABLE TO HANDLE LARGE VOLUME OF CONDENSATE |
| HPV-401 |
12.5 |
40 |
1/2" |
<80 / 23 |
YES |
HIGH PRESSURE SUITABLE FOR
CONDENSATE HAVING SLUDGE & OIL |
| SSD-ZAL-151 |
5 |
15 |
1/2" |
<80 / 23 |
YES
WITH
STRAINER |
SUITABLE ABOVE 80 CFM WITH
ZERO AIR LOSS. |
| PNLD-121 |
12.5 |
12 |
1/2" |
<80 / 23 |
YES |
ZERO AIR LOSS. SUITABLE FOR LARGE
COMPRESSOR MORE THEN 80 CFM AND CONDENSATE HAVING SLUDGE &OIL |
| PNLD-151 |
3.5 |
15 |
1/2" |
<80 / 23 |
YES |
ZERO AIR LOSS. SUITABLE
UP TO 80 CFM |
| MOIST MINDER |
5 |
12 |
1/2" |
<80 / 23 |
YES
WITH
STRAINER |
ZERO AIR LOSS. SUITABLE
UP TO 80 CFM |
REMARKS < 1 HP = 3.5 CEM
0.596 CEM = M/HR |